No. |
Safety device name |
Bridge crane |
Gantry crane |
Loading bridge |
1 |
Overload limiter |
Starting weight> 20t must be installed |
Starting weight> 10t must be installed |
Should be installed |
3 ~ 20t lifting capacity must be installed |
3 ~ 10t lifting capacity must be installed |
|||
2 |
Up limit position limiter |
Power-driven should be installed |
Power-driven should be installed |
Should be installed |
3 |
Down limit position limiter |
Power-driven adapted to be attached |
Power-driven adapted to be attached |
Should be installed |
4 |
Movement limit position limiter |
Power-driven in carts and trolleys run limit position should be installed |
||
5 |
Chain protection |
① should be installed |
① should be installed |
② should be installed |
6 |
Buffer |
Should be installed |
Should be installed |
Should be installed |
7 |
Rail clamp anchoring device |
Outdoor work shall be installed |
Outdoor work shall be installed |
Outdoor work shall be installed |
8 |
Boarding signal button |
There should be mounted cab |
There should be mounted cab |
Cab should be installed in the moving part |
9 |
Anti-rollover safety hook |
Single main beam and the main beam side should be installed off the hook |
|
|
10 |
Maintenance hoists |
Should be installed |
Should be installed |
Should be installed |
11 |
Sweep rails and supporting frame |
Should be installed |
Should be installed |
Should be installed |
12 |
Track plate end stop |
Should be installed |
Should be installed |
Should be installed |
13 |
Slip line shield |
Should be installed |
|
|
14 |
Exposed moving parts shields |
Should be installed |
Should be installed |
Should be installed |
15 |
Electrical Equipment Covers |
Outdoor work shall be installed |
Outdoor work shall be installed |
Outdoor work shall be installed |
Note:
① For the bridge crane, crane from the building board between the door and the traveling mechanism; boarded by the cab door hatch bridge and trolley run institutions; located in the sports section of the cab into the cab openings and trolley run institutions, should be installed interlock protection.
② For the loading bridge, located in the cab of the moving part of the channel at the mouth into the cab and trolley run institutions, shall be equipped with interlock protection.